EnglishFrenchSpanish

OnWorks favicon

netperfmeter - Online in the Cloud

Run netperfmeter in OnWorks free hosting provider over Ubuntu Online, Fedora Online, Windows online emulator or MAC OS online emulator

This is the command netperfmeter that can be run in the OnWorks free hosting provider using one of our multiple free online workstations such as Ubuntu Online, Fedora Online, Windows online emulator or MAC OS online emulator

PROGRAM:

NAME


netperfmeter — Network Performance Meter

SYNOPSIS


netperfmeter [Port]
netperfmeter [Destination:Port] -local=Address[,Address,...] -runtime=Seconds -config=Name
-scalar=Name -vector=Name -activenodename=Description
-passivenodename=Description -quiet -verbose -verbosity=Level -tcp -mptcp -sctp
-udp -dccp [FLOWSPEC] [...]

DESCRIPTION


netperfmeter is a network performance meter for the UDP, TCP, MPTCP, SCTP and DCCP transport
protocols. It simultaneously transmits bidirectional flows to an endpoint and measures the
resulting flow bandwidths. The results are written as vector and scalar files.

ARGUMENTS


The following arguments have to be provided:

Port The port number for the passive side's data socket. The port number of the control
socket will be port+1. Specifying a port number turns netperfmeter in passive mode,
i.e. it will wait for incoming connections.

Destination:Port
Specifies the destination endpoint to connect to. This will turn netperfmeter in
active mode, i.e. it will connect to the specified remote endpoint.

local=Address[,Address,...]
Specifies address(es) of the local endpoint. For TCP, UDP and DCCP, only the first
address is used!

runtime
Specifies the measurement runtime in seconds. After the given time span,
netperfmeter will finish the measurement.

config=Name
Specifies the name of the configuration file to write. Default is output.config.

vector=Name
Specifies the name pattern of the vector files to write. If the suffix of this name
is .bz2, the file will be BZip2-compressed on the fly. The vector name is
automatically extended to name the flow vector files by adding
-<active|passive>-<flow_id>-<stream_id> before the suffix. Default is
vector.vec.bz2, hence the name of the vector file for flow 5, stream 2 on the
passive node will be vector-passive-00000005-0002.vec.bz2.

scalar=Name
Specifies the name pattern of the scalar files to write. If the suffix of this name
is .bz2, the file will be BZip2-compressed on the fly. The scalar name is
automatically extended to name the flow scalar files by adding
-<active|passive>-<flow_id>-<stream_id> before the suffix. Default is
scalar.vec.bz2, hence the name of the scalar file for flow 5, stream 2 on the
passive node will be scalar-passive-00000005-0002.vec.bz2.

activenodename=Description
Sets a textual description of the active node (e.g. Client).

passivenodename=Description
Sets a textual description of the passive node (e.g. Server).

quiet Reduces verbosity of log output. May be specified multiple times.

verbose
Increases verbosity of log output. May be specified multiple times.

verbosity=Level
Sets the verbosity of the log output to a given level, from 0 (lowest) to 6
(highest).

sctp Establish a new SCTP association. The streams of this association must be specified
by one or more FLOWSPEC specifications as following parameters.

tcp Establish a new TCP or MPTCP connection. The flow of this connection must be
specified by a FLOWSPEC specification as following parameter. MPTCP support in
NetPerfMeter is realized as additional "MPTCP" socket (i.e. another TCP socket, but
bound to another port number and with CMT enabled). That is, for MPTCP usage, it
must contain the option cmt=mptcp (see below) to usage the MPTCP socket instead of
the TCP socket.

udp Establish a new UDP connection. The flow of this connection must be specified by a
FLOWSPEC specification as following parameter.

dccp Establish a new DCCP connection. The flow of this connection must be specified by a
FLOWSPEC specification as following parameter. Note, that DCCP is not available on
all platforms yet. Currently, only Linux provides DCCP in its official kernel.

FLOWSPEC
Specifies a new flow. The format is:
outgoing_frame_rate:outgoing_frame_size:incoming_frame_size:incoming_frame_rate:option:...
The first four parameters
(outgoing_frame_rate:outgoing_frame_size:incoming_frame_size:incoming_frame_rate:option)
may be substituted by the option "default", creating a flow with some more or less
useful default parameters.

outgoing_frame_rate
The frame rate of the outgoing transfer (i.e. active node to passive node).
If set to const0, the sender will be saturarted, i.e. it will try to send as
much as possible.

outgoing_frame_size
The frame size of the outgoing transfer (i.e. active node to passive node).
If set to const0, there will be *no* data transmission in this direction.

incoming_frame_rate
The frame rate of the incoming transfer (i.e. passive node to active node).
See outgoing_frame_rate for details.

incoming_frame_size
The frame size of the incoming transfer (i.e. active node to passive node).
See outgoing_frame_size for details.

Possible options:

id=Flow Identifier
Sets an ID number for the flow. The IDs within a measurement must be
unique!

description=Description
Sets a textual description of the flow (e.g. HTTP-Flow). Do not use
spaces in the description!

maxmsgsize=Bytes
Splits frames into messages of at most the given number of bytes.
Messages may not exceed 65535 bytes.

defragtimeout=Milliseconds
Messages not received within this timeout after the last
successfully received message are accounted as lost. NOTE: this also
happens if the transport protocol is reliable and the message is
actually received later!

unordered=Fraction
Specifies the fraction of the messages that will be sent in
unordered mode (SCTP only).

ordered=Fraction
Specifies the fraction of the messages that will be sent in ordered
mode (SCTP only).

reliable=Fraction
Specifies the fraction of the messages that will be sent in reliable
mode (SCTP only).

unreliable=Fraction
Specifies the fraction of the messages that will be sent in
unreliable mode (SCTP only).

rtx_timeout=Milliseconds
Sets the retransmission timeout for unreliable messages (SCTP only;
not available on all platforms!)

rtx_trials=Trials
Sets the retransmission trials for unreliable messages (SCTP only;
not available on all platforms!)

rcvbuf=Bytes
Sets the receiver buffer size to the given number of bytes.

sndbuf=Bytes
Sets the sender buffer size to the given number of bytes.

onoff=t1,t2,...
A list of time stamps when the flow should be activated or
deactivated. If onoff is given, the flow is off at startup. At t1,
it will be turned on; at t2, it will be turned off, etc.. Time
stamps can be given as absolute values (e.g. onoff=0,10,30 - to turn
on at t=0, turn off at t=10 and turn on again at t=30 until end of
measurement) or relative values (e.g. on=10,+30,+60 - to turn on at
t=10, turn off at t=40 and turn on again at t=100 until end of
measurement).

error_on_abort=on|off
By default, the active side stops with an error when a transmission
tails (e.g. on connection abort). This parameter turns this
behaviour on or off.

cmt=off|cmt|cmtrpv1|cmtrpv2|like-mptcp|mptcp-like|mptcp
Configures usage of Concurrent Multipath Transfer (CMT): off (turned
off; default), cmt (independent paths), cmtrpv1 (CMT/RPv1), cmtrpv1
(CMT/RPv2), mptcp/like-mptcp/mptcp-like (MPTCP), 0-255 (custom
value). Currently only supported by CMT-SCTP on FreeBSD systems and
MPTCP on Linux systems. Note: CMT for MPTCP always uses MPTCP
congestion control.

EXAMPLES


Some netperfmeter usage examples:

netperfmeter 9000
Start in passive mode, i.e. accepting connections, on port 9000.

netperfmeter 172.16.255.254:9000 -vector=output.vec.bz2 -scalar=output.sca.bz2 -sctp
const5:exp1000:const3:exp500:description="Alpha":onoff=+10
const5:exp1000:const3:exp500:description="Beta":onoff=+30 -tcp
const5:exp1000:const3:exp500:description="Gamma":onoff=+60 -runtime=300
Start in active mode, i.e. establish connection to 172.16.255.254, port 9000.
Frames will be segmented into messages of up to 4096 bytes. Write vectors to
output.vec.bz2 (BZip2-compressed). Write scalars to output.sca.bz2
(BZip2-compressed). Establish SCTP association. At t=10s, start flow "Alpha" as
first stream of this association, using a frame rate of 5 (constant) and average
frame size of 1000 bytes (negative exponential distribution) for the outgoing data
and a frame rate of 3 (constant) and average frame size of 500 bytes (negative
exponential distribution) for the incoming data. At t=30s, start flow "Beta" as
second stream on the SCTP association (same parameters as flow "Alpha"). Start TCP
connection. At t=60s, start flow "Gamma" over the TCP connection (same parameters
as flow "Alpha"). At t=300s, stop the measurement.

AUTHORS


Thomas Dreibholz
http://www.iem.uni-due.de/~dreibh/netperfmeter
mailto://[email protected]

Use netperfmeter online using onworks.net services


Free Servers & Workstations

Download Windows & Linux apps

  • 1
    subconverter
    subconverter
    Utility to convert between various
    subscription format. Shadowrocket users
    should use ss, ssr or v2ray as target.
    You can add &remark= to
    Telegram-liked HT...
    Download subconverter
  • 2
    SWASH
    SWASH
    SWASH is a general-purpose numerical
    tool for simulating unsteady,
    non-hydrostatic, free-surface,
    rotational flow and transport phenomena
    in coastal waters as ...
    Download SWASH
  • 3
    VBA-M (Archived - Now on Github)
    VBA-M (Archived - Now on Github)
    Project has moved to
    https://github.com/visualboyadvance-m/visualboyadvance-m
    Features:Cheat creationsave statesmulti
    system, supports gba, gbc, gb, sgb,
    sgb2Tu...
    Download VBA-M (Archived - Now on Github)
  • 4
    Stacer
    Stacer
    Linux System Optimizer and Monitoring
    Github Repository:
    https://github.com/oguzhaninan/Stacer.
    Audience: End Users/Desktop. User
    interface: Qt. Programming La...
    Download Stacer
  • 5
    OrangeFox
    OrangeFox
    Fork of TeamWinRecoveryProject(TWRP)
    with many additional functions, redesign
    and more Features:Supports Treble and
    non-Treble ROMsUp-to-date Oreo kernel,
    built...
    Download OrangeFox
  • 6
    itop - ITSM  CMDB OpenSource
    itop - ITSM CMDB OpenSource
    IT Operations Portal: a complete open
    source, ITIL, web based service
    management tool including a fully
    customizable CMDB, a helpdesk system and
    a document man...
    Download itop - ITSM CMDB OpenSource
  • More »

Linux commands

Ad